Human Inflammation Antibody Array C3 (AAH-INF-3) – 40 Inflammatory Cytokines on One Membrane

The RayBiotech Human Inflammation Antibody Array C3 (cat. no. AAH-INF-3) profiles 40 human inflammation-related proteins on a single membrane — IL-1α, IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, IL-13, IL-17A, TNF-α, TNF-β, IFN-γ, MCP-1, MIP-1α/β, RANTES, IP-10, ICAM-1, GM-CSF, M-CSF, TGF-β1, soluble TNF receptors and more. It is one of the most widely used first-screen arrays for inflammation, immunology and macrophage studies. Changyu Biotech supplies it worldwide; request a quote.

Key specifications

Catalog numberAAH-INF-3 (RayBiotech)
SpeciesHuman
Targets40 inflammation-related cytokines, chemokines and receptors
FormatMembrane antibody array (sandwich)
DetectionChemiluminescence (imager or X-ray film)
OutputSemi-quantitative, relative levels between samples
UseResearch use only

Where it fits

  • Macrophage polarization and immune-cell activation (THP-1, PBMC, primary macrophage supernatants).
  • Drug or compound screening for anti-inflammatory effects.
  • Serum/plasma profiling in inflammatory disease cohorts before targeted ELISA.
  • Comparing tissue lysates from disease vs control.

Membrane vs glass vs quantitative

  • C3 membrane (this page): no special equipment, semi-quantitative.
  • Glass-slide G-Series: laser-scanner read-out, smaller sample volume.
  • Quantitative (Quantibody) inflammation arrays: absolute concentrations for each target.
  • Rat models: see the Rat Cytokine Array GS282 for a 282-target rat screen.

Common questions

What does the Human Inflammation Antibody Array C3 detect?

It detects 40 human inflammation-related proteins on one membrane, including IL-1β, IL-6, IL-8, IL-10, TNF-α, IFN-γ, MCP-1, RANTES, ICAM-1, TGF-β1 and GM-CSF.

Is the inflammation array quantitative?

The C-Series membrane array is semi-quantitative (relative levels). For absolute concentrations, choose a quantitative inflammation array or ELISA for key targets.

What samples are suitable?

Serum, plasma, cell culture supernatants and lysates are typical; see the kit manual for recommended volumes and dilutions.

Do I need a special scanner?

No. Detection is chemiluminescent, read on a standard imager or X-ray film.

Related RayBiotech arrays

Published with this array

Ma et al., Nature Biomedical Engineering 2025 — CAR T cell therapy screening on an immunocompetent leukaemia chip: the array profiled cytokine crosstalk between CAR T cells and the bone marrow niche.

Scroll to Top